The European Committee for Standardization is one of three European Standardization Organizations (together with CENELEC and ETSI) that have been officially recognized by the European Union and by the European Free Trade Association (EFTA) as being responsible for developing and defining voluntary standards at European level.

 - 

 
sdg-main
This standard contributes to the following SDG:
  •  

Project

Reference prEN ISO 11073-10421
Title Health informatics - Device interoperability - Part 10421: Personal Health Device Communication - Device Specialization- Peak expiratory flow monitor (peak flow) (ISO/IEEE FDIS 11073-10421:2024)
Work Item Number 00251404
Abstract/Scope This document establishes a normative definition of communication between personal telehealth peak flow monitoring devices (agents) and managers (e.g., cell phones, personal computers, personal health appliances, and set top boxes) in a manner that enables plug-and-play interoperability. It leverages work done in other ISO/IEEE 11073 standards including existing terminology, information profiles, application profile standards. It specifies the use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability. This document defines a common core of functionality of a peak-flow monitoring device. The use case is restricted to personal respiratory monitoring and therefore does not include hospital-based spirometry. Continuous and high-acuity monitoring (e.g., for emergency response) are outside the scope of the use case. In the context of personal health devices, a peak flow meter is a device is used to measure the respiratory function of those managing respiratory conditions such as asthma and chronic obstructive pulmonary disease. The ability to identify declining respiratory status prior to the need for acute intervention improves the quality of life for the individual while reducing the overall costs of care. Respiratory status data are collected by a personal respiratory monitoring device and forwarded to a central data repository for review and action by a health care provider. The data are episodic in nature and are forwarded at designated intervals or when the person is symptomatic.
Status
Under Approval
Reference Document
ISO/IEEE 11073-10421:2024 (EQV)
date of Availability (DAV)  
ICS 35.240.80 - IT applications in health care technology
A-Deviation(s)  
Special National Condition(s)  

Legal

Directive(s)  
Mandate(s)  
Citation in OJEU  

Implementation Dates

date of Ratification (DOR) (1)  
date of Availability (DAV) (2)  
date of Announcement (DOA) (3)
date of Publication (DOP) (4)
date of Withdrawal (DOW) (5)

Relations

Supersedes EN ISO 11073-10421:2012
Superseded by  

(1) Date of ratification (dor) date when the Technical Board notes the approval of an EN (and HD for CENELEC), from which time the standard may be said to be approved


(2) Date of availability (dav) date when the definitive text in the official language versions of an approved CEN/CENELEC publication is distributed by the Central Secretariat


(3) Date of announcement (doa) latest date by which the existence of an EN (and HD for CENELEC), a TS or a CWA has to be announced at national level


(4) Date of publication (dop) latest date by which an EN has to be implemented at national level by publication of an identical national standard or by endorsement


(5) Date of withdrawal (dow) latest date by which national standards conflicting with an EN (and HD for CENELEC) have to be withdrawn


(6) This list of normative references is purely indicative. The only official list of normative reference is the list of the published standard.


In the case of undated standard, a link to the last dated version is provided.


In the case of series, a link to each standard identified in the series is provided.


We also invite you to check (via the website) whether corrigenda and/or amendments shall be read in conjunction with the main standard.

 

Our use of cookies

We use necessary cookies to make our site work.

Necessary cookies enable core functionality such as security, network management, and accessibility. You may disable these by changing your browser settings, but this may affect how the website functions.

  翻译: