A Builder's EV Swap Kit! Builders want a kit that they can install easily, without programming controllers or pin wiring harnesses. Legacy EV makes it easy for builders to complete the wiring harnesses for your build by terminating and testing all HV and LV wiring before it ships out. This reduces the time to install an Atom Drive EV conversion system from months to days. #ampereev #atomdrivesystem #ev #evswap #evconversion #icetoev #electricvehicle #electricvehicles #SEMA2024 #SEMAShow #SEMAShow2024 #SEMA #SEMAGarage
Ampere EV’s Post
More Relevant Posts
-
When it is Essential to fit an Input Choke to Inverter Drives Small and Medium sized Drives without internal DC Chokes need a relatively soft supply, to keep the input Current within the design range. Use on a High Fault Level supply will have high rms and high harmonic Current. The Solution is to fit 1%, 2% or 4% Input Chokes. Medium to Large Drives with internal DC Chokes, need 1% minimum supply impedance, to complete protection of the front-end diodes/thyristors. If this not available in the supply, the Solution is to fit 1% (minimum) Input Chokes. An Input Choke reduces Voltage transients and other supply disturbances in a weaker supply, or Applications where a sliding busbar or brush-gear provides the incoming power supply. Voltage Drop of 9.2V, 4.6V and 2.3V approximately will be present across 4%, 2% and 1% Chokes. Excessive Voltage Drop will cause reduced torque available at the motor. If there is an option to fit an external DC Choke, Voltage drop will be reduced. References for 400V Drives: - WEG CFW100 0.18kW to 1.5kW. 1% Minimum Supply Impedance. Page 16 (3.2.3.2). WEG CFW300 0.37kW to 7.5kW. 1% Minimum Supply Impedance. Page 18 (3.2.3.2). WEG CFW500 0.18kW to 22kW. 1% Minimum Supply Impedance. Page 19 (3.2.3.2). WEG CFW501 0.18kW to 7.5kW. 1% Minimum Supply Impedance. Page 19 (3.2.3.1). ABB ACS180 0.55kW to 22kW. 0.3% Minimum Supply Impedance. Page 120. ABB ACS480 0.55kW to 22kW. ABB Listed chokes over 5kA and 10kA. Page 161 & 144. Yaskawa GA500 0.55kW to 22kW Use a choke in supply over 600kVA. Page 96 (3.12). Yaskawa GA700 0.75kW to 22kW Use a choke in supply over 600kVA. Page 125 (2.21). Yaskawa GA700 30kW to 315kW Internal DC Choke included. Page 75 (2.11 *3). This is intended as a general guide and the Manufacturers recommendations and requirements should always be followed. The Inverter Drive Supermarket Limited accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation. Copyright - The Inverterdrive Supermarket Limited. https://lnkd.in/ex6Cvsec
To view or add a comment, sign in
-
Programming for Schneider inverter ATV 320 to control an electric elevator. Before practical implementation, I implemented and simulated first using Yaskawa j1000 inverter. The following was required: 1) A program to control the elevator via selector button and specify a direction for forward and a direction for reverse, thus controlling it remotely from the terminal control circuit. 2) Control the frequency to a value of 40 Hz and control it locally. 3) Do ramping stopping and starting so that during start the motor ramps for 5 seconds and during stop press, ramping is done for 3 seconds. 4) DC injection operates at half the motor rated current for 5 seconds during start and 3 seconds during stop. 5) Use the button to create an eternal fault and use three different speeds to control the elevator speed.📝📝🧷♥
To view or add a comment, sign in
-
🔔 The ATV312H018M2 is a model of variable frequency drive (VFD) manufactured by Schneider Electric. It is part of the Altivar 312 series, which is designed to control the speed and torque of three-phase motors in a wide range of applications, particularly for simple and standard processes. Here are some key features and specifications of the ATV312H018M2: ✅ Power Rating: 18.5 kW (approximately 25 HP) motor power capacity. ✅Voltage Rating: Typically operates with a 380-480 V AC supply. ✅Control Type: Vector control and V/f control modes. ✅Enclosure: It usually comes in a compact, IP20 enclosure suitable for installation in electrical panels. ✅Applications: Widely used in applications such as pumps, fans, conveyors, and compressors. ✅Communication Protocols: Includes Modbus RTU, CANopen, and optionally other communication protocols for integration into various control networks. ✅Built-in Functions: Features built-in motor protection, energy-saving functions, and multiple user-defined settings. This VFD is designed for applications requiring simple motor control with reliable performance and energy efficiency. Would you like to know more specific details about this drive or its installation and usage? 📞 Call me:+86-15880802917 📧 Email:sale2@indautoparts.com
To view or add a comment, sign in
-
To test alternator diodes with a multimeter, set the multimeter to diode test mode. Connect the multimeter's positive lead to the alternator's output terminal and the negative lead to the alternator's case (ground). A good diode will show a low reading in one direction (typically 0.5-0.8 volts) and a high resistance or OL (open loop) in the reverse direction. Repeat for each diode.
To view or add a comment, sign in
-
Industrial Drives & Applications ===================== 1-An introduction to electrical drives & their dynamics 2-Selection of motor power rating 3&4-DC Motor Drives 5&6-Induction motor drives 7-Synchronous motor drives 8-Industrial drives #Free_Palestine
To view or add a comment, sign in
-
E310PLUS INVERTER TECO 2HP ~ 3HP 220V 3HP ~ 5HP 380V Technical Specifications: ● Support V/F and Vector control modes ● Detachable keypad ● Output up to 150% torque at 1Hz frequency ● Start-up after speed tracking mode ● PID control ● Maximum output frequency 400Hz ● RS-485 Modbus communication ● Support Autotune operation ● Support AutoRun operation #inverter #inverter_teco #Teco_E310Plus #Industrial_Inverter #Variable_Frequency_Drive #VFD #Motor_Control #Energy_Efficiency #Industrial_Automation