We are here for you! Drop us email and we will take care of your #CT or #MR #injector PM and repairs
Sure Medical’s Post
More Relevant Posts
-
Dear friends, In this post, I want to explain the requirements for medical beds according to IEC 60601-2-52 standard which has been published in 2015. At the beginning of this standard five application environments have been explained that the manufacturer has to select based on its product and its function. Although all of these requirements are necessary, in my opinion, the mechanical requirements are more important. Based on these requirements, we have to check all hazardous parts, including moving (sub-clause 201.9.2.2.2) and non-moving parts (sub-clause 201.9.1.101), carefully using some tools and digital caliper, because some of these zones can be fatal for the patients (see more in annex AA of this standard). Another part of this standard checks the instability of EUT (Equipment Under Test) based on the marked maximum patient weight and safe working load. The strength and latch reliability of the side rail tests according to a long-time test which has been explained in sub-clause 201.9.8.3.3.3. As an expert, we have to check the range of movement of the back section and leg section. The limitation of movement has been explained in sub-clause 201.15.4.6.2 based on the structure of EUT. I'll be happy if you send me feedback. #ProductAssessor #TechnicalReviewer #CertificationEngineer #MedicalDeviceRegulation #MDR #FieldTechnician
To view or add a comment, sign in
-
Research and manufacturing of a series of production equipment, including square aluminum shell power cell, pouch cell (polymer), cylindrical cell, etc., and technical support for cells manufacturing
Fully automatic liquid injection machine
To view or add a comment, sign in
-
Following up on last week’s discussion (see link in the comments): amazing to see there is no official name yet for the equivalent of drawdown during injection (so: BHP-Pres)! Here’s a list of the suggested names. What is your preferred name for the equivalent of drawdown during injection? LinkedIn only allows for a poll with 5 options, so just state your favorite in the comments. If there is a clear winner I will start using this term from now on! · (Injection) delta P / dP · Excess injection pressure · Injection differential · Net injection pressure · Build-up pressure · Drawdown · Pressure overdraw · Pressure up-swing · Incremental pressure · dP step-up
To view or add a comment, sign in
-
𝐓𝐡𝐞 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐫𝐨 𝐐𝐮𝐚𝐧𝐭𝐢𝐭𝐚𝐭𝐢𝐯𝐞 𝐅𝐢𝐭 𝐓𝐞𝐬𝐭𝐞𝐫 The 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐫𝐨 Fit Tester has all the capabilities you need to accurately it ALL mask types. It’s a simple, easy to use device that includes OSHA’s streamlined 2019 CNC protocol. Rugged, quick to deploy and fully featured, the affordable 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐫𝐨 provides the answers you need in a format you can use and comes with a standard 3 year warranty. The 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐫𝐨 is fully adaptable for elastomeric and disposable respirators and features proven CNC fit testing technology and conforms to OSHA testing standards. The following types of respirators can be tested with the 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐫𝐨: 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐑𝐎 𝐊𝐞𝐲 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬: • Fit test all tight-fitting full & half mask respirators • 7” color touch screen • Stand-alone of PC operation • Control up to 4 units simultaneously with independent start/stop times • Two modes of operation for particle size range • WiFi enabled • 6 language options • OSHA, ANSI, CSA, HSE protocol compliant • CNC technology • 3 USB ports & 1 Ethernet port • 3 year warranty 𝐑𝐞𝐬𝐩𝐢𝐫𝐚𝐭𝐨𝐫𝐬 𝐭𝐡𝐚𝐭 𝐜𝐚𝐧 𝐛𝐞 𝐟𝐢𝐭 𝐭𝐞𝐬𝐭𝐞𝐝 𝐮𝐬𝐢𝐧𝐠 𝐭𝐡𝐞 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐫𝐨: • All full face = ALL • All half face = ALL • NIOSH series 99 = ALL • NIOSH series 100 = ALL • P1 = ALL • P2 = ALL • P3 = ALL • N95 = ALL • KN95 = ALL 𝐀𝐜𝐜𝐮𝐅𝐈𝐓𝟗𝟎𝟎𝟎 𝐏𝐫𝐨 𝐏𝐚𝐜𝐤𝐚𝐠𝐞 𝐈𝐧𝐜𝐥𝐮𝐝𝐞𝐬: • AccuFIT9000 Pro instrument • Rugged, hardsided shipping/carrying case • AccuPunch N95 probe installation tool • Inlet probes & retainers for N95 mask (pack of 500) • Twin tubing • AC adapter • 99.5% reagent grade alcohol (pack of 12 - 60ml bottles) • AccuFIT testing software • USB cable • Ultrasonic Humidifier (Particle Generator) • Operation & service manuals • Factory calibration certificate If you are in the following states (IN, IL, WI, MN, MI, OH, KY) AFC International, Inc. is going to be your official authorized distributor for the AccuFIT9000 Series fit testers. Give us a call today for more information, pricing and availability. 𝟏-𝟖𝟎𝟎-𝟗𝟓𝟐-𝟑𝟐𝟗𝟑 𝐨𝐫 𝐬𝐚𝐥𝐞𝐬@𝐚𝐟𝐜𝐢𝐧𝐭𝐥.𝐜𝐨𝐦 #fittest #fittesting #quantitative #oshacompliance #osha #respiratory #respiratoryprotection #respiratorycompliance #lifesafety #healthcare #ems #fireservice #lawenforcement #ehs #safetymanagers #hospitalsafety #employeehealth
To view or add a comment, sign in
-
THE PERFECTION! Sterilization processes in pharmaceutical applications are subject to very stringent parameters, imposed by the reference regulations and involve exposure to very harsh conditions of temperature, humidity, vacuum and pressure for the products to be treated. As an integral and fundamental part of the process, the temperature probes are therefore also exposed to the same conditions and, despite appearing to be structurally simple products, they are, together with the pressure sensor, a key component of the process and its implementation requires expert hands, specific know-how and highly specialized staff. CAP IT produces a precision PT100 sensor ideal for autoclave or “walk-in” applications. With over a decade of performance proven in the field and thanks to incessant work, which began over twenty years ago and has intensified in recent years, the CAP IT PT100 sensor for autoclaves is a highly performing product, with unique performances, undoubtedly the best in Italy, exclusive and inimitable, such that it can be defined as the PERFECT SENSOR. Inserted directly into the systems via specific cable glands and positioned near the product to be treated, it is subjected to extremely harsh working conditions, due to the often joint action of temperature, steam, pressure and vacuum. The experience, the chosen materials and some exclusive technologies make it extremely resistant, durable and precise and, for this reason, highly appreciated by the major manufacturers and users of autoclaves. Completely waterproof, CAP IT's PT100 sensor is manufactured and designed to withstand the repeated and penetrating steam/vacuum cycle of the autoclave process and high handling and handling stress, yet maintaining the highest levels of accuracy and repeatability beyond which provides excellent flexibility and manual use for operators. PT 100 OHM PROBE FOR AUTOCLAVE / Autoclave PT100 Probe Technical features: PT100 Ohm sensitive element Accuracy class “AA” (1/3 DIN) Single or double element Protective sheaths in AISI 316 L Teflon® insulated and silicone coated 4/8 conductor cables, Bar Code and Serial Number Conformity and Calibration Report on request Operating temperature up to 150°C and above Operation above 3 BAR of saturated vapor pressure and vacuum. #sterilization #rtdforautoclaves #RTD #autoclaves #temperaturedetection #temperature
To view or add a comment, sign in
-
Cleanroom Testing By VOV. Let's get to know the Leak Scanner. Identify leaks on HEPA or ULPA filters. Explain and compare to make things easier to understand. Not overly technical. Otherwise, puzzled. 🔬 Leak Scanner is a long tube. Used for "leak detection" One end of the tube contains a particle-detecting channel. Install a display screen. A module is located at the cable's termination point. It's a box for measuring leaks. The device also includes a display screen. 🚨 Testing method The user utilizes the Leak Scanner to determine the value at the Filter face. By simultaneously releasing chemicals into the air intake passage. If the Leak Scanner detects the sample chemical, it signifies that there is a leak in the filter. 👩🚀 However, the test must be performed by a professional engineer only. ⭐ Ask for information and reserve a Clean Room testing appointment ⭐ 📌 Chat now: https://lnkd.in/gd6a-4CS 📧 Email: media@vovgroup.com ☎ Call: 098-556-9387 ❇ LINE OA: @cleanroom #cleanroom #cleanroom #Negativepressureroom #Positivepressureroom #Pharmaceuticalproductionroom #Laboratory #Productionroom #Industrialroom #Dustproofroom #Cleanroomknowledge #ICR #BCR #Cleanroomkit #PPEkit #Cleanroomtesting #Createcleanroom
To view or add a comment, sign in
-
Keep Your Astell Autoclave in Top Shape: Quick Tips from DH Lab 🔬 1️. Routine Checks: Follow Astell’s daily, weekly, and monthly maintenance guidelines. 2️. Annual Service: Get a qualified technician to perform a full service every year. 3️. Regulatory Compliance: Stay up to date with local regulations and standards such as ISO 17025, and pressure system regulations (PSSR 2000 in the UK and S.I. 445 2012 in ROI) 4️. Record Keeping: Document all maintenance and calibrations for easy audit readiness. 5️. Usage Matters: Adjust service frequency based on how often your autoclave is used. 6. Calibration: UKAS accredited calibration to ensure your process is meeting your specific thermal requirements. If you would like more information on our autoclaves, sign up here! https://lnkd.in/eG56z85d #LabMaintenance #Autoclave #Compliance #DHLab
To view or add a comment, sign in
-
The #SECULIFE and #SECUTEST device safety testers include all of the required test functions for testing the effectiveness of protective measures in electrical medical, welding and other devices. Protective earth/ground bond, earth leakage, touch leakage, applied parts leakage, Insulation Resistance and other tests all in one meter. http://ow.ly/9bna50F9ZU1 #gmcinstruments #safety
To view or add a comment, sign in
-
With my extensive experience and knowledge, supplying tablet tooling and other production equipment across Asia, earned over the past 16 years in the Pharma industry. I am available to help you achieve better solutions.
WHY DO I NEED... PHARMACARE® STEP 3: REPAIR The repair stage allows the user to rectify minor damage to the tooling before polishing. Minor damage and corrosion can be repaired using a motorised chuck. If damage is excessive, tools must be replaced. In all cases it is important to remember that repair to punches and dies should only be carried out when absolutely necessary as this can potentially change tooling dimensions resulting in other tableting problems. Regular maintenance and repair work will help to extend tooling life, maintain tablet image and definition, optimize tooling productivity and prevent tooling breakages. I Holland offer a range of consumable products which can be bought separately, or as a complete maintenance kit (including the UC500, electronic polishing unit, polishing motor, comparators, motorised chuck and consumables products which help for the repair work) #ihollandlimited #pharmacare #7steps #repair #optimizetoolingproductivity
To view or add a comment, sign in
20 followers