Electrical Design Series -04 Earthing Transformer Sizing Calculation The sizing of an earthing transformer depends on several factors, including the system voltage, fault current level, and the desired level of impedance for the grounding system. The purpose of an earthing transformer is to provide a low-impedance path to ground for fault currents. To determine the size of an earthing transformer, you need to consider the following: 1. System voltage: The rated voltage of the earthing transformer should match the system voltage it is connected to. This ensures compatibility and proper operation. 2. Fault current level: The size of the earthing transformer should be selected based on the maximum fault current that can occur in the system. This is typically determined through fault studies and calculations. 3. Grounding system impedance: The earthing transformer should have a low enough impedance to provide a ground fault current path. The impedance is typically specified as a percentage or an ohmic value. The selection of the earthing transformer depends on the desired level of impedance for the grounding system. 4. Transformers rating: The earthing transformer should be rated to handle the expected fault currents without its thermal and insulation limits. 5. Cooling requirements: The size of the earthing transformer may also depend on the cooling method used, such as natural convection, forced air, or liquid cooling The cooling method should be selected based on the transformer's expected loading and operating conditions. A good document is attached to go through the Earthing transformer design and its sizing criteria. #electricalengineering #powersystems #electricaldesignengineer #electricaldesign #renewablepower #detaildesign #FEED #powergeneration #

ARASAKUMARAN R

BE-EEE - With Electrical "C" Competency Certified(Licenced),10+ Years Experience in Plant Maintenance, Electrical Machinery Maintenance, Mechanical, Electrical Switchgear,Control, Monitoring,Fault analysis Etc.

10mo

Electrical Calculation Excel Speardsheet #repost, #share, #fresher, #knowledge 1.Calculating the Transformer IDMT Over Current & Earth Fault Relay Setting (Excel) https://lnkd.in/ecB4asqf 2.Calculate the Size of Capacitor For Power Factor Improvements (Excel) https://lnkd.in/eZATrjnT 3.Calculate Size of DOL & Star Delta Starter (Excel) https://lnkd.in/eTxkxxHa 4.Calculate Insulation Resistance Value(Excel) https://lnkd.in/eHKPyBdB 5.Calculate Electrical Unit Consumption & Energy Bill https://lnkd.in/eabNQNPC 7.Calculating the Motor-Pump Size https://lnkd.in/ebgdFMMx 8.Calculating the Size of aircondition for room(Excel) https://lnkd.in/esYSmt7G 9. C.B Tripping Setting & Fuse for Motor Protection(Excel) https://lnkd.in/e-zSgNmj 10.Selection of Main /Branch Circuit MCB as per NEC-210 https://lnkd.in/e3JgnGJ5 11.Electrical Cable size Selection and Voltage Drop Calculation https://lnkd.in/eAnjemCT 12. Polarization Index Value Measurement(Excel Speardsheet) https://lnkd.in/enkpA_su 13.Earth Resistance Value Calculation (Excel Speardsheet) https://lnkd.in/ekjPFHBc

need a downloadable version of this artical

Like
Reply
Deenadayalan Rajavelu

Senior Electrical Engineer -Oil and Gas EPC

11mo

kVA rating missing in section 4.proposed grounding transformer

Like
Reply
Salamullah Afridi

Electrical Estimation|AutoCAD Drafter| QS cum Drafter(Advanced CAD Expertise)| Electrical Project Execution|Versatile in Residential & Commercial Projects| Electrical Fit-out Projects|Site Supervision & Inspection•

11mo

Very useful👍

Like
Reply
Irwansyah Putra

Export-Import General Trading & Supplier // Tlp/Whatsapp : 0856-8947-476 // Phone: +6221-8949-4216 Fax: +6221-8949-4217

11mo

  • No alternative text description for this image
Like
Reply
Waqas Ahmad Chaudhry

Power System Studies Engineer | Electrical Substation Design Engineer | ETAP, PSS/E | Power System Analysis Instructor | Technical Instructor |14+ Years Exp.

11mo

Very useful

Like
Reply
Irshad Ahmed Shaikh

Rig Electrician at ADES - Advanced Energy Systems

11mo

Thanks for sharing

Like
Reply
See more comments

To view or add a comment, sign in

Explore topics