Planning Engineer & Coordinator

33 Kv power supply without power outage #electrical #transmission #line #power #distribution #engineer #knowledge #technician

Graham Peter Gissing

Operational Protection Engineer at UK Power Networks Services

7mo

If a company tells you that is a safe working practice you should leave and never look back.

Borislav Kostadinov Karachorov CEng, MSc, PMP

Lead Telecoms Engineer / PM with extensive experience within Oil & Gas industry

7mo

In my opinion and experience, its not a safe practice , and impossible to do on a 33kV power line. Example shown Looks like much lower voltage at first, and second - the power line is being damaged so you already have a power outage, don't you ..? 🤪 If there is any kind of protection implemented on tbis power grid, and provided it is fully functional and not being intentionally disabled, it would trip the power supply at this line at one of the ends at least, and after the joint it would trip the supply at both ends.

Ridwan J

Engineer - Well Completion & Open Hole Liner Hanger

7mo

That's another example of unsate job. As long as the basket is not isolated from the ground, and difference potential of electro current did not equalized between wire and employee, there is very likelihood high voltage shock, other than that an employee must be worn special PPE, with 75 % Nomex for fire retardant and 25% stainless steel, which is create a faraday cage around him, to avoid electro current shock.

Like
Reply
Ashok Kumar

Head Reliability Engineering Vedanta Ltd | MBA

7mo

Hot line maintenance can be accomplished using either the faraday cage method or the hot stick method. Specialized training on hot line maintenance is conducted in NPTI Bangalore, India.

Khaled V.

Senior Telecom Consultant Engineer at Self-employed

7mo

Why is there No Plastic Sheathing on the connection to safeguard from the elements (weather, Corrossions). There should be No Exposure to the elements.

Daryl Geraldo

Lineman crew at MERALCO

7mo

Hello sir how how to apply pls help to apply your company thank you

Like
Reply
Zayan Konilakath

Substation supervisor Operations, Monitoring & Inspection of 400/220/132/66/33/22/11kV GIS & AIS Transmission Substation's with 4+ Experience.

7mo

Work done without safety is unacceptable. Safety regulations should be a priority for us when it comes to electricity. One becomes truly brave when one works with all safety.

Gilbert Slaven

Retired OLE Manager IOSH

7mo

Would it be better to change the ceramic insulators to polymeric save on maintenance duties

Like
Reply
Pabitra Kumar Sahoo

Deputy Manager at Ajanta Pharma Ltd

7mo

Hazard identification & risk mitigation plan necessary in every business. Arc Flash may create severe burn injury.