Niraj Pandya’s Post

View profile for Niraj Pandya, graphic

Rotary, Static and Packages Engineering Manager @ Free Lancer | Process, Mechanical and Thermal Designing

-Interesting Case study for Pvelite users 516 Gr 70 Vessel( Shell-Dish) MDMT = -40 Deg C De.Pr= 1.38 Mpa Dia= 3.5m and OAL =6.6m Shell Thk and Dish need to find out in the Software. How to save from Impact test. 😊 ( Which is Must ) Do this in your free time and let me know.

Nikunj Kavadia

Static Equipment Design Engineer at Worley

1y

-Use Normaized MOC, and - uncheck the option of the "use the vessel mawp to compute the mdmt" So based on stress ratio higher mdmt reduction can be availed or use mawp and design pressure as same to take advantage of stress ratio for further mdmt reduction. - Increase minor thickness if required for higher mdmt reduction due to lower stress ratio if there is small difference between computed mdmt and actual mdmt.

Mukesh Prajapati

Sr. Mechanical Engg. - Package and Static equipment

1y

What's the reason of -40 deg C MDMT?

Mukesh Prajapati

Sr. Mechanical Engg. - Package and Static equipment

1y

is it because of de-pressurization scenario?

ankit kumar

Static equipment design engineer

1y

Impact tested